|
SourceForge net
auto-phlip-ml Auto Phlip Ml, supplied by SourceForge net, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/auto+phlip+ml/us10179312-245-5-6 Average 90 stars, based on 1 article reviews
auto-phlip-ml - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
ChinaPeptides
phlip (98) Phlip (98), supplied by ChinaPeptides, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/phlip++98+/pmc06432225-40-26-31 Average 90 stars, based on 1 article reviews
phlip (98) - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
AnaSpec
nbd-x se ![]() Nbd X Se, supplied by AnaSpec, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/nbd+x+se/pmc05567424-86-9-21 Average 90 stars, based on 1 article reviews
nbd-x se - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Iris Biotech Gmbh
phlip icg ![]() Phlip Icg, supplied by Iris Biotech Gmbh, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/icg+phlip/pmc07591906-25-15-25 Average 86 stars, based on 1 article reviews
phlip icg - by Bioz Stars,
2026-11
86/100 stars
|
Buy from Supplier |
|
GL Biochem
phlip ![]() Phlip, supplied by GL Biochem, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/phlip/pmc09281440-46-0-4 Average 90 stars, based on 1 article reviews
phlip - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
SourceForge net
phlip a " width="250" height="auto" />Phlip, supplied by SourceForge net, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/phlip+software/pmc10268615-14-69-6 Average 90 stars, based on 1 article reviews
phlip - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
CS Bio Inc
phlip-cys a " width="250" height="auto" />Phlip Cys, supplied by CS Bio Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/phlip+cys/10__1161_slash_circresaha__121__320296-60-14-16 Average 90 stars, based on 1 article reviews
phlip-cys - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
GL Biochem
nh2-aeqnpiywaryadwlfttplllldlallvdadegt (phlip a " width="250" height="auto" />Nh2 Aeqnpiywaryadwlfttplllldlallvdadegt (Phlip, supplied by GL Biochem, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/nh2+aeqnpiywaryadwlfttplllldlallvdadegt++phlip/pm39558766-375-0-5 Average 90 stars, based on 1 article reviews
nh2-aeqnpiywaryadwlfttplllldlallvdadegt (phlip - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
GenScript corporation
alkynyl-terminated phlip a " width="250" height="auto" />Alkynyl Terminated Phlip, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/alkynyl+terminated+phlip/pm29493121-181-2-22 Average 90 stars, based on 1 article reviews
alkynyl-terminated phlip - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
CS Bio Inc
phlip® variant 3 (var3) peptide a " width="250" height="auto" />Phlip® Variant 3 (Var3) Peptide, supplied by CS Bio Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/phlip++variant+3++var3++peptide/us11779662-1109-107-134 Average 90 stars, based on 1 article reviews
phlip® variant 3 (var3) peptide - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
AAT Bioquest
dnp-maleimide a " width="250" height="auto" />Dnp Maleimide, supplied by AAT Bioquest, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/dnp+maleimide/pm36686229-55-2-4 Average 90 stars, based on 1 article reviews
dnp-maleimide - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Philips Healthcare
phlips hdi 5000 a " width="250" height="auto" />Phlips Hdi 5000, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/g+e+phlip+composite+peptide/5000+hdi/ppr0626138-41-9-12 Average 86 stars, based on 1 article reviews
phlips hdi 5000 - by Bioz Stars,
2026-11
86/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Biophysical Journal
Article Title: Determination of the Membrane Translocation p K of the pH-Low Insertion Peptide
doi: 10.1016/j.bpj.2017.06.065
Figure Lengend Snippet: The pHLIP does not have a unique pK value. Bars correspond to the pK determined by W fluorescence SM, spectral CM, or FI, by CD, or by Nt-NBD or Ct-NBD of pHLIP. Mean values are shown, for experiments repeated three to six times, and error bars are the SD. Color shading represents groups with no statistical difference. ∗p ≤ 0.05; ∗∗p ≤ 0.01; ∗∗∗p ≤ 0.005; NS; no significance.
Article Snippet: For the conjugation of NBD to the N-terminus of
Techniques: Fluorescence
Journal: Biophysical Journal
Article Title: Determination of the Membrane Translocation p K of the pH-Low Insertion Peptide
doi: 10.1016/j.bpj.2017.06.065
Figure Lengend Snippet: NBD conjugates of pHLIP display different pK values based on location. (A and B) Representative emission spectra of pHLIP-NBD (A) and NBD-pHLIP (B) show an increase in fluorescence intensity as acidity is increased (shaded arrows). (C and D) Normalized fluorescence intensity at 540 nm is plotted versus pH to determine pKCt-NBD (C) and pKNt-NBD (D). Lines in (C) and (D) show the fits of Eq. 2 to the data. Solid arrows mark the approximate pH values for the start and end of the titrations.
Article Snippet: For the conjugation of NBD to the N-terminus of
Techniques: Fluorescence
Journal: Biophysical Journal
Article Title: Determination of the Membrane Translocation p K of the pH-Low Insertion Peptide
doi: 10.1016/j.bpj.2017.06.065
Figure Lengend Snippet: Intrinsic W, Nt-NBD, and Ct-NBD fluorescence display similar kinetics during pHLIP membrane insertion. Given here are average spectra of W (dark shaded), Nt-NBD (dashed light shaded), and Ct-NBD (solid) in POPC.
Article Snippet: For the conjugation of NBD to the N-terminus of
Techniques: Fluorescence, Membrane
Journal: Biophysical Journal
Article Title: Determination of the Membrane Translocation p K of the pH-Low Insertion Peptide
doi: 10.1016/j.bpj.2017.06.065
Figure Lengend Snippet: Qualitative comparison of fluorescence pK titrations with ssNMR pKa titrations for the individual aspartate residues. The individual titrations for D14 (magenta), D25 (blue), D31 (green), and D34 (red) obtained by Hanz et al. (10) are overlaid with the fluorescence data obtained following tryptophan SM (A) and FI (B), and pHLIP-NBD (C). The ssNMR data were represented by the fitting to the Boltzmann equation (10). Normalized chemical shifts are shown for a better comparison, and values were inverted in (B) and (C) to align with the fluorescence data changes.
Article Snippet: For the conjugation of NBD to the N-terminus of
Techniques: Comparison, Fluorescence
Journal: Biophysical Journal
Article Title: Determination of the Membrane Translocation p K of the pH-Low Insertion Peptide
doi: 10.1016/j.bpj.2017.06.065
Figure Lengend Snippet: Tentative model showing the transition from State II to State III during the membrane insertion of pHLIP, highlighting the insertion step/s that each pK value reports on. The solid arrows represent the transitions between each step in the membrane insertion process, with the corresponding pH midpoints. The change of the D residues from shaded to solid represents the protonation. CD, and potentially SM and CM, reports on the insertion process encompassing D33, D31, and D25, and are then shown labeling the first three transitions. FI and Nt-NBD follow the protonation of D14, and to a lesser extent D25 and D33 (not shown in figure). Finally, Ct-NBD reports on the last insertion step, where the C-terminal end translocates across the bilayer.
Article Snippet: For the conjugation of NBD to the N-terminus of
Techniques: Membrane, Labeling
Journal: Scientific Reports
Article Title: pHLIP ICG for delineation of tumors and blood flow during fluorescence-guided surgery
doi: 10.1038/s41598-020-75443-5
Figure Lengend Snippet: Characterization of pHLIP ICG and blood clearance in mice and dogs. ( a ) The Var3 pHLIP sequence is shown with the chemical structure of the ICG dye coupled to a single Cys residue at the N-terminal part of pHLIP peptide. ( b ) Normalized absorbance (black line) and fluorescence (red line) spectra (the excitation is at 805 nm) of pHLIP ICG (5 µM) measured in DMF. ( c ) Circular dichroism (CD) spectra of pHLIP ICG measured in phosphate buffer (pH 8) in absence (pHLIP ICG, pH 8—black line) and presence (pHLIP ICG + PC, pH 8—blue line) of POPC liposomes, and in the presence of POPC liposomes at pH 5.2 (pHLIP ICG + PC, pH 5.2—red line) indicate on formation of helical structure in membrane at low pH. ( d ) pH-dependent insertion of pHLIP ICG into the bilayers of POPC liposomes monitored by changes of the CD spectral signal at 222 nm. The data were fitted with the Henderson-Hasselbach equation (red line with 95% confidence interval) to establish the midpoint of the transition (pK). ( e ) The kinetics signal (multiplied by − 1) of pHLIP ICG insertion into lipid bilayers of POPC liposomes as a result of a pH drop from pH 8 (blue line in insert) to pH 5 (red line in insert) was monitored in real-time by the tryptophan fluorescence changes (black line). The gray line is a baseline obtained by mixing pHLIP ICG with POPC liposomes at pH 8 with pH 8 buffer. The red line is a bi-exponential fit of the experimental data (85% of the signal changes occur with a rate of 5 s −1 and about 15% of final adjustment is completed at a rate of 0.077 s −1 ). ( f , g ) Blood clearance profile and single exponential fitting curves (red lines) obtained from mice ( f ) and dogs ( g ) after a single i.v. injection of 12.3 mg/kg of pHLIP ICG to mice and 0.064 mg/kg of pHLIP ICG to dogs are shown.
Article Snippet: All manufacturing procedures were completed in accordance with good laboratory practice (GLP) quality control specifications.
Techniques: Sequencing, Residue, Fluorescence, Circular Dichroism, Liposomes, Membrane, Injection
Journal: Scientific Reports
Article Title: pHLIP ICG for delineation of tumors and blood flow during fluorescence-guided surgery
doi: 10.1038/s41598-020-75443-5
Figure Lengend Snippet: Imaging of blood vessels in mice. Representative NIR pHLIP ICG fluorescent images of blood vessels at different time points after a single i.v. injection of ICG-Cys ( a ) or pHLIP ICG ( b ).
Article Snippet: All manufacturing procedures were completed in accordance with good laboratory practice (GLP) quality control specifications.
Techniques: Imaging, Injection
Journal: Scientific Reports
Article Title: pHLIP ICG for delineation of tumors and blood flow during fluorescence-guided surgery
doi: 10.1038/s41598-020-75443-5
Figure Lengend Snippet: Imaging of blood vessels in pigs. Representative NIR pHLIP ICG (verification batch #1912127) fluorescent images and overlay of fluorescent and color images of blood vessels at different time points after injection of pHLIP ICG in PBS (dose 1—0.052 mg/kg; dose 2—additional 0.12 mg/kg; dose 3—additional 0.24 mg/kg) are shown. ( a ) Imaging inside the pig body cavity was performed using a Stryker 1688 AIM system (808 nm excitation) for endoscopic/laparoscopic imaging (gain 8/10 for dose 2, gain 7/10 for dose 3). ( b ) Imaging of a pedicle flap was performed using a Stryker SPY-PHI handheld device (805 nm excitation) for open-field imaging.
Article Snippet: All manufacturing procedures were completed in accordance with good laboratory practice (GLP) quality control specifications.
Techniques: Imaging, Injection
Journal: Scientific Reports
Article Title: pHLIP ICG for delineation of tumors and blood flow during fluorescence-guided surgery
doi: 10.1038/s41598-020-75443-5
Figure Lengend Snippet: Tumor targeting. Representative photos and overlay of photos and in vivo NIR pHLIP ICG fluorescent images of athymic female nude mice bearing murine and human tumors are shown with skin removed from the tumor site. Targeting of human breast MDA-MB-231 tumor ( a ), murine breast 4T1 tumor ( b ), human A549 lung tumor ( c ), murine LLC Lewis lung carcinoma ( d ), human M4A4 epithelial tumor ( e ), human HeLa cervical tumor ( f ), human UMUC3 urinary bladder tumor ( g ) and human prostate LNCaP tumor ( h ) are shown. The imaging was performed at 24 h after a single i.v. administration of pHLIP ICG. Arrows indicate tumor locations. In the case of the MDA-MB231 breast tumor model, both a small tumor (arrow at the right) and an inguinal lymph node (indicated as LN) are targeted.
Article Snippet: All manufacturing procedures were completed in accordance with good laboratory practice (GLP) quality control specifications.
Techniques: In Vivo, Imaging
Journal: Scientific Reports
Article Title: pHLIP ICG for delineation of tumors and blood flow during fluorescence-guided surgery
doi: 10.1038/s41598-020-75443-5
Figure Lengend Snippet: Ex vivo imaging of tumors with surrounding muscle. Representative photos, and overlays of photos and ex vivo NIR pHLIP ICG fluorescent images of tumors resected with surrounding tissue immediately after in vivo imaging. Targeting of human breast MDA-MB-231 tumor ( a ), murine breast 4T1 tumor ( b ), human A549 lung tumor ( c ), murine LLC Lewis lung carcinoma ( d ), human M4A4 epithelial tumor ( e ), human HeLa cervical tumor ( f ), human UMUC3 urinary bladder tumor ( g ) and human prostate LNCaP tumor ( h ) are shown. In the case of the MDA-MB231 breast tumor model, both a small tumor and an inguinal lymph node (indicated as LN) are targeted.
Article Snippet: All manufacturing procedures were completed in accordance with good laboratory practice (GLP) quality control specifications.
Techniques: Ex Vivo, Imaging, In Vivo Imaging
Journal: Scientific Reports
Article Title: pHLIP ICG for delineation of tumors and blood flow during fluorescence-guided surgery
doi: 10.1038/s41598-020-75443-5
Figure Lengend Snippet: Ex vivo imaging and imaging of sections. ( a ) Representative images of tumors with surrounding tissue: photos, NIR pHLIP ICG fluorescent images, overlay of photos with NIR pHLIP ICG fluorescent images, and images of HE-stained sections obtained from the same tumor-muscle pieces are shown. ( b ) Bright field image of HE-stained section and NIR pHLIP ICG fluorescent images of the adjacent non-processed section obtained on IR scanner shown in monochrome (green) and 16-color (white and red are the highest intensity, and black and dark blue are the lowest intensity) presentations. T indicates tumor; M indicates muscle, and S indicates stroma. ( c ) Magnified bright field images (using 20 × objective) of tumor (T), muscle (M1 and M2), tumor stroma (TS1, TS2 and TS3) of HE-stained section are presented in panel ( b ).
Article Snippet: All manufacturing procedures were completed in accordance with good laboratory practice (GLP) quality control specifications.
Techniques: Ex Vivo, Imaging, Staining
a " width="100%" height="100%">
Journal: ACS Omega
Article Title: Tools of the Trade: Image Analysis Programs for Confocal Laser-Scanning Microscopy Studies of Biofilms and Considerations for Their Use by Experimental Researchers
doi: 10.1021/acsomega.2c07255
Figure Lengend Snippet: Overview of Image Analysis Programs for Biofilm Confocal Micrographs with a Focus on Tool Scope and Selection of Relevance to Experimental Researchers
Article Snippet:
Techniques: Selection, Fluorescence, Bacteria, Staining, Cytometry, Labeling, Cell Counting, Introduce, Filtration, Activity Assay, Software, Microscopy